Disassembly
METER: COMBINATION METER: DISASSEMBLY
DISASSEMBLY
1. REMOVE NO. 1 COMBINATION METER BRACKET
(a) Remove the 4 screws and bracket.
2. REMOVE COMBINATION METER GLASS
(a) Remove the 2 screws.
(b) Detach the 6 claws and remove the meter glass.
3. REMOVE METER DISPLAY PANEL
(a) Remove the 12 screws and meter cover.
(b) Detach the 6 claws to remove the locks.
(c) Disconnect each flat cable.
(d) Remove the display panel from the meter ECU.