Back-Up Power Source Circuit
AIR CONDITIONING: AIR CONDITIONING SYSTEM: Back-up Power Source Circuit
Back-up Power Source Circuit
DESCRIPTION
The back-up power source circuit for the A/C amplifier is shown below. Power is supplied even when turning the engine switch off and is used for diagnostic trouble code memory, etc.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT FUSE (A/C)
(a) Remove the A/C fuse from the cowl side junction block LH.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
NG -- REPLACE FUSE (A/C)
OK -- Continue to next step.
2. INSPECT AIR CONDITIONING AMPLIFIER (AIR CONDITIONING AMPLIFIER - BODY GROUND)
(a) Disconnect the A/C amplifier connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE