Installation
HEATING / AIR CONDITIONING: AIR CONDITIONING PRESSURE SENSOR: INSTALLATION
1. INSTALL AIR CONDITIONING PRESSURE SENSOR
(a) Sufficiently apply compressor oil to a new air conditioning pressure sensor.
Compressor oil:
ND-OIL 11 or equivalent
NOTICE:
* Keep the O-ring and O-ring fitting surfaces clean from dirt or any foreign objects.
* Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.
(b) Install the new air conditioning pressure sensor.
Torque : 11 Nm (110 kgf-cm, 8 ft-lbf)
NOTICE:
* Do not deform the piping.
* Make sure to confirm that the piping does not disengage from the plastic clamp.
(c) Connect the connector.
2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL Installation
3. INSTALL LUGGAGE COMPARTMENT FLOOR MAT Installation
4. CHARGE WITH REFRIGERANT Service and Repair
5. WARM UP COMPRESSOR Service and Repair
6. INSPECT FOR REFRIGERANT LEAK Service and Repair