P0A1A
L110F HYBRID VEHICLE CONTROL: HYBRID CONTROL SYSTEM: P0A1A-200,P0A1A-792,P0A1A-793: Generator Control Module
P0A1A-793 - Generator Control Module
DESCRIPTION
The inverter with converter assembly (MG ECU) monitors its internal operation and detects malfunctions.
MONITOR DESCRIPTION
The MG ECU performs many diagnostic tests to verify proper operation of internal ECU systems. In this diagnostic monitor, the MG ECU checks for an R/D (Resolver/Digital Converter) malfunction involving the generator resolver. If MG ECU detects an R/D error, it will conclude that there is an internal malfunction involving the generator resolver. The hybrid vehicle control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
HINT
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
1. CHECK DTC OUTPUT (HV)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
(d) Check if DTCs are output.
Result:
B -- GO TO DTC CHART Hybrid Control System
A -- Continue to next step.
2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
NOTICE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.
(a) Turn the power switch off.
(b) Remove the service plug grip Hybrid Control System.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.
(c) Check the connection of the low voltage connector of the inverter with converter assembly.
OK:
The connector is connected securely and there are no contact problems.
HINT
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
NG -- CONNECT SECURELY
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
CAUTION:
Be sure to wear insulated gloves.
(a) Disconnect the low voltage connector from the inverter with converter assembly.
(b) Turn the power switch on (IG).
(c) Measure the voltage according to the value(s) in the table below.
Standard voltage:
NOTICE:
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
4. CHECK GENERATOR RESOLVER
(a) Turn the power switch off.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open):
Standard resistance (Check for short):
NG -- CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
OK -- Continue to next step.
5. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
(a) Turn the power switch on (IG).
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
NOTICE:
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.
6. CHECK MOTOR RESOLVER
(a) Turn the power switch off.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open):
Standard resistance (Check for short):
NG -- CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
OK -- Continue to next step.
7. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
(a) Check the connection of the generator resolver connector.
OK:
The connector is connected securely and there are no contact problems.
NG -- CONNECT SECURELY
OK -- Continue to next step.
8. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
(a) Check the connection of the motor resolver connector.
OK:
The connector is connected securely and there are no contact problems.
NG -- CONNECT SECURELY
OK -- REPLACE INVERTER WITH CONVERTER ASSEMBLY Installation
9. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
(a) Check the connection of the generator resolver connector.
OK:
The connector is connected securely and there are no contact problems.
NG -- CONNECT SECURELY
OK -- Continue to next step.
10. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
(a) Disconnect the generator resolver connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open):
Standard resistance (Check for short):
HINT
The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Components
11. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
(a) Check the connection of the motor resolver connector.
OK:
The connector is connected securely and there are no contact problems.
NG -- CONNECT SECURELY
OK -- Continue to next step.
12. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
(a) Disconnect the motor resolver connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for open):
Standard resistance (Check for short):
HINT
The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE HYBRID VEHICLE TRANSMISSION ASSEMBLY Components