P3233





L110F HYBRID VEHICLE CONTROL: HYBRID CONTROL SYSTEM: P3233-750: Short to B+ in Blocking of HV Gate Connection
P3233-750 - Short to B+ in Blocking of HV Gate Connection

DESCRIPTION

Refer to the description for DTC P3232-749 P3232.





WIRING DIAGRAM

Refer to the wiring diagram for DTC P3232-749 P3232.

INSPECTION PROCEDURE

CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
HINT
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

PROCEDURE

1. CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

(a) Turn the power switch off.





(b) Remove the service plug grip Hybrid Control System.

NOTICE:
After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.

(c) Disconnect connector A76 from the hybrid vehicle control ECU.

(d) Disconnect the low voltage connector from the inverter with converter assembly.

(e) Turn the power switch on (IG).

(f) Measure the voltage according to the value(s) in the table below.

Standard voltage:





NOTICE:
Turning the power switch on (IG) with the connector of the hybrid vehicle control ECU or the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

(g) Turn the power switch off.

(h) Measure the resistance according to the value(s) in the table below.

Standard resistance:





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.

2. CHECK INVERTER WITH CONVERTER ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

(a) Check that the service plug grip is not installed.

(b) Measure the resistance according to the value(s) in the table below.





Standard resistance:





NG -- REPLACE INVERTER WITH CONVERTER ASSEMBLY Installation

OK -- REPLACE HYBRID VEHICLE CONTROL ECU Components