P0A1A-166 - Generator Control Module
HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM: P0A1A-166: Generator Control Module
P0A1A-166 - Generator Control Module
DESCRIPTION
The MG ECU located in the inverter with converter assembly monitors its internal operation and it will set DTCs when it detects malfunctions. If any of the following DTCs are output, replace the inverter with converter assembly.
MONITOR DESCRIPTION
The MG ECU performs many diagnostic tests to verify proper operation of internal ECU systems. In this diagnostic monitor, the MG ECU checks for an R/D (Resolver/Digital Converter) malfunction involving the generator resolver. If MG ECU detects an R/D error, it will conclude that there is an internal malfunction involving the generator resolver. The power management control ECU (HV CPU) will illuminate the MIL and set a DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
COMPONENT OPERATING RANGE
CONFIRMATION DRIVING PATTERN
1. Connect the Techstream to the DLC3.
2. Turn the power switch on (IG) and turn the Techstream on.
3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
4. Turn the power switch off.
5. Turn the power switch on (READY) and allow MG2 to rotate at 50 rpm or more for 30 seconds, then turn the power switch off. [A]
6. Repeat [A] 3 times. [B]
7. Turn the power switch on (IG) and turn the Techstream on.
8. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
9. Check that permanent DTCs are cleared.
10. If the permanent DTCs are not cleared, perform the universal trip, and then check for permanent DTCs again.
HINT
- If a permanent DTC is output, the system is malfunctioning.
- If no permanent DTC is output, the system is normal.
INSPECTION PROCEDURE
PROCEDURE
1. REPLACE INVERTER WITH CONVERTER ASSEMBLY
(a) Replace the inverter with converter assembly Components.
NEXT -- COMPLETED