P0A1A-793 - Generator Control Module





HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM: P0A1A-200, P0A1A-792, P0A1A-793: Generator Control Module
P0A1A-793 - Generator Control Module

DESCRIPTION

The inverter with converter assembly (MG ECU) monitors its internal operation and detects the following malfunctions.





MONITOR DESCRIPTION

The MG ECU performs many diagnostic tests to verify proper operation of internal ECU systems. In this diagnostic monitor, the MG ECU checks for an R/D (Resolver/Digital Converter) malfunction involving the generator resolver. If MG ECU detects an R/D error, it will conclude that there is an internal malfunction involving the generator resolver. The power management control ECU (HV CPU) will illuminate the MIL and set a DTC.

MONITOR STRATEGY





TYPICAL ENABLING CONDITIONS





TYPICAL MALFUNCTION THRESHOLDS





COMPONENT OPERATING RANGE





CONFIRMATION DRIVING PATTERN





1. Connect the Techstream to the DLC3.

2. Turn the power switch on (IG) and turn the Techstream on.

3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4. Turn the power switch off.

5. Turn the power switch on (READY) and allow MG2 to rotate at 50 rpm or more for 30 seconds, then turn the power switch off. [A]

6. Repeat [A] 3 times. [B]

7. Turn the power switch on (IG) and turn the Techstream on.

8. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]

9. Check that permanent DTCs are cleared.

10. If the permanent DTCs are not cleared, perform the universal trip, and then check for permanent DTCs again.

HINT
- If a permanent DTC is output, the system is malfunctioning.
- If no permanent DTC is output, the system is normal.

WIRING DIAGRAM





INSPECTION PROCEDURE

CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Hybrid Control System: Precaution.
HINT
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Service Precautions.

PROCEDURE

1. CHECK DTC OUTPUT (HYBRID CONTROL)

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

(d) Check if DTCs are output.

Result:









(e) Turn the power switch off.

B -- GO TO DTC CHART (HYBRID CONTROL SYSTEM) Hybrid Control System
A -- Continue to next step.

2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

(a) Check that the service plug grip is not installed.

NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.

NOTICE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.





(b) Check the connection of the low voltage connector of the inverter with converter assembly.

OK:

The connector is connected securely and there are no contact problems.

HINT
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.

NG -- CONNECT SECURELY
OK -- Continue to next step.

3. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

(a) Disconnect the low voltage connector D28 from the inverter with converter assembly.

(b) Turn the power switch on (IG).

(c) Measure the voltage according to the value(s) in the table below.





Standard Voltage:





Text in Illustration





NOTICE:
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

(d) Turn the power switch off.

(e) Connect the low voltage connector from the inverter with converter assembly.

NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.

4. CHECK GENERATOR RESOLVER

(a) Disconnect the low voltage connector D28 from the inverter with converter assembly.

(b) Measure the resistance according to the value(s) in the table below.





Standard Resistance (Check for Open):





Standard Resistance (Check for Short):





Text in Illustration





(c) Connect the inverter with converter assembly connector.

NG -- CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
OK -- Continue to next step.

5. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

(a) Disconnect the low voltage connector D28 from the inverter with converter assembly.

(b) Turn the power switch on (IG).

(c) Measure the voltage according to the value(s) in the table below.





Standard Voltage:





Text in Illustration





NOTICE:
Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

(d) Turn the power switch off.

(e) Connect the inverter with converter assembly connector.

NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- Continue to next step.

6. CHECK MOTOR RESOLVER

(a) Disconnect the low voltage connector D28 from the inverter with converter assembly.

(b) Measure the resistance according to the value(s) in the table below.





Standard Resistance (Check for Open):





Standard Resistance (Check for Short):





Text in Illustration





(c) Connect the inverter with converter assembly connector.

NG -- CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
OK -- Continue to next step.

7. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)

(a) Check the connection of the generator resolver connector.

OK:

The connector is connected securely and there are no contact problems.





NG -- CONNECT SECURELY
OK -- Continue to next step.

8. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)

(a) Check the connection of the motor resolver connector.

OK:

The connector is connected securely and there are no contact problems.





NG -- CONNECT SECURELY

OK -- REPLACE INVERTER WITH CONVERTER ASSEMBLY Components

9. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)

(a) Check the connection of the generator resolver connector.

OK:

The connector is connected securely and there are no contact problems.





NG -- CONNECT SECURELY
OK -- Continue to next step.

10. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

(a) Disconnect the low voltage connector D28 from the inverter with converter assembly.

(b) Disconnect the generator resolver connector.





(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):





Standard Resistance (Check for Short):





Text in Illustration





HINT
The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

(d) Connect the generator resolver connector.

(e) Connect the inverter with converter assembly connector.

NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR

OK -- REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY Components

11. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)

(a) Check the connection of the motor resolver connector.

OK:

The connector is connected securely and there are no contact problems.





NG -- CONNECT SECURELY
OK -- Continue to next step.

12. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

(a) Disconnect the low voltage connector D28 from the inverter with converter assembly.

(b) Disconnect the motor resolver connector.





(c) Measure the resistance according to the value(s) in the table below.

Standard Resistance (Check for Open):





Standard Resistance (Check for Short):





Text in Illustration





HINT
The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

(d) Connect the motor resolver connector.

(e) Connect the inverter with converter assembly connector.

NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR

OK -- REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY Components