Ambient Light Sensor: Testing and Inspection
LIGHTING (EXT): AUTOMATIC LIGHT CONTROL SENSOR: INSPECTION
1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR
(a) Disconnect the K1 automatic light control sensor connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Text in Illustration
If the result is not as specified, there is a malfunction on the wire harness side.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
If the result is not as specified, there is a malfunction on the wire harness side.
(d) Reconnect the K1 automatic light control sensor connector.
(e) Check the waveform of the K1 automatic light control sensor connector.
OK:
HINT
If the ambient light becomes brighter, width A becomes narrower.
If the result is not as specified, the automatic light control sensor may have a malfunction.