Compressor HVAC: Testing and Inspection
HEATING / AIR CONDITIONING: COMPRESSOR (for 2GR-FSE): INSPECTION
1. INSPECT A/C COMPRESSOR
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
If the resistance is not as specified, replace the A/C compressor.
Text in Illustration
2. INSPECT MAGNETIC CLUTCH
(a) Measure the resistance of the connector.
Standard Resistance:
If the resistance is not as specified, replace the magnetic clutch.
Text in Illustration
(b) When connector terminal A1 is connected to the positive (+) battery terminal, check that the following occurs: 1) the magnetic clutch's operating sound can be heard, and 2) the magnetic clutch's hub and rotor lock.
3. INSPECT A/C COMPRESSOR (LOCK SENSOR)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
If the resistance is not as specified, replace the A/C compressor.
Text in Illustration
4. INSPECT A/C COMPRESSOR (SOLENOID)
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
If the resistance is not as specified, replace the A/C compressor.
Text in Illustration