Entire Combination Meter Does Not Operate
METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: Entire Combination Meter does not Operate
- Entire Combination Meter does not Operate
DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source. If a voltage of 12 V is not applied to terminal IG2 when the power switch is turned on (IG), the indicators will not operate.
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
(a) Disconnect the H19 connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
(c) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Text in Illustration
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE COMBINATION METER ASSEMBLY Removal