Instruments - Compass Calibration Procedure
L-SB-0115-11September 20, 2011
Initial Calibration of Compass During PDS
Service Category
General
Section
Pre-Delivery Service
Market
USA
Applicability
Introduction
Some 2012 model CT 200h vehicles are equipped with a compass in the rear view mirror. In order for the compass to correctly indicate the direction that the vehicle is heading it must be calibrated prior to vehicle delivery. Use the appropriate procedure (depending on mirror type) to perform initial calibration during Pre-Delivery Service (PDS).
Warranty Information
Calibration Procedure
Type A & B
1. Cycle the ignition switch to the "IG-ON" position and hold the "AUTO" switch until the zone number appears on the display.
2. Push the "AUTO" switch to select the number of the zone where the vehicle is located.
3. Start the engine and push the "AUTO" switch until "CAL" appears on the display.
For Type A & B
1. Drive the vehicle slowly at 5 mph (8 km/h) or less in a circle until the direction is displayed. If there is NOT enough space to drive in a circle drive around the block until the direction is displayed.
Once the direction is displayed the calibration is complete.