Heated Oxygen Sensor
2GR-FE EMISSION CONTROL: HEATED OXYGEN SENSOR: INSPECTION
1. INSPECT HEATED OXYGEN SENSOR
(a) Measure the resistance between terminals 1 (HT) and 2 (+B).
Standard resistance:
If the result is not as specified, replace the sensor.