Inspection
2UR-GSE ENGINE CONTROL: CAMSHAFT OIL CONTROL VALVE: INSPECTION
1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
If the result is not as specified, replace the oil control valve.
(b) Connect a battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.
OK:
If the result is not as specified, replace the oil control valve.
NOTICE:
Do not allow foreign matter to contact the oil seal face of the oil control valve (the surface that contacts the cylinder head cover sub-assembly).
HINT
If the valve cannot return properly because of foreign matter, a small pressure leak in the advance direction may occur and a DTC may be stored.