Operation CHARM: Car repair manuals for everyone.

Installation





2UR-GSE ENGINE CONTROL: IGNITION COIL AND SPARK PLUG: INSTALLATION

1. INSTALL SPARK PLUG

(a) Using a 16 mm plug wrench, install the 8 spark plugs.





Torque : 21 Nm (214 kgf-cm, 15 ft-lbf)

2. INSTALL IGNITION COIL ASSEMBLY

(a) Install the 8 ignition coils with the 8 bolts.





NOTICE:
Do not damage the ignition coils when installing them.

Torque : 9.0 Nm (92 kgf-cm, 80 in-lbf)

(b) Connect the 8 ignition coil connectors.

3. INSTALL WIRE HARNESS CLAMP BRACKET

(a) Install the wire harness clamp bracket with the bolt.





Torque : 8.0 Nm (82 kgf-cm, 71 in-lbf)

(b) Install the wire harness clamp to the clamp bracket.

(c) Install the No. 7 engine room relay block with the 2 bolts and nut.





Torque : 8.0 Nm (82 kgf-cm, 71 in-lbf)

4. INSTALL BATTERY TRAY

(a) Install the battery tray with the 3 bolts.





Torque : 5.4 Nm (55 kgf-cm, 48 in-lbf)

5. INSTALL POWER STEERING ECU ASSEMBLY Installation

6. INSTALL NO. 1 BATTERY TRAY SUPPORT

7. INSTALL BATTERY

(a) Install the battery.

(b) Install the battery insulator.

(c) Install the battery clamp with a nut.

Torque : 2.9 Nm (30 kgf-cm, 26 in-lbf)

(d) Connect the cable to the positive (+) battery terminal.

Torque : 5.4 Nm (55 kgf-cm, 48 in-lbf)

(e) Connect the 2clamps.





8. INSTALL AIR CLEANER CAP SUB-ASSEMBLY Installation

9. INSTALL ENGINE ROOM SIDE COVER LH Installation

10. INSTALL ENGINE ROOM SIDE COVER RH Installation

11. INSTALL COOL AIR INTAKE DUCT SEAL Installation

12. INSTALL V-BANK COVER SUB-ASSEMBLY Installation

13. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

(a) Connect the cable to the negative (-) battery terminal.

Torque : 5.4 Nm (55 kgf-cm, 48 in-lbf)

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.