Disassembly
METER: COMBINATION METER: DISASSEMBLY
1. REMOVE NO. 1 COMBINATION METER BRACKET
(a) Remove the 4 screws and bracket.
2. REMOVE COMBINATION METER GLASS
(a) Remove the 2 screws.
(b) Detach the 6 claws and remove the meter glass.
3. REMOVE COMBINATION METER COVER
(a) Remove the 12 screws and meter cover.
4. REMOVE METER DISPLAY PANEL
(a) Detach the 6 claws and disconnect each wire harness.
(b) Remove the display panel from the meter ECU.