Operation CHARM: Car repair manuals for everyone.

P0A1B-788





L110F HYBRID VEHICLE CONTROL: HYBRID CONTROL SYSTEM: P0A1B-788: Drive Motor "A" Control Module
P0A1B-788 - Drive Motor "A" Control Module

DESCRIPTION

If the inverter with converter assembly (MG ECU) is reset due to a problem with the power source in the inverter, the hybrid vehicle control ECU will set this DTC.





MONITOR DESCRIPTION

If an abnormal power source IC CPU reset is detected in the MG ECU, the hybrid vehicle control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY





TYPICAL ENABLING CONDITIONS





TYPICAL MALFUNCTION THRESHOLDS





COMPONENT OPERATING RANGE





CONFIRMATION DRIVING PATTERN





1. Connect the Techstream to the DLC3.

2. Turn the power switch on (IG) and turn the Techstream on.

3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4. Turn the power switch off.

5. Turn the power switch on (READY), and then after 1 minute or more, turn the power switch off. [A]

6. Repeat [A] 3 times. [B]

7. Turn the power switch on (IG) and turn the Techstream on.

8. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]

9. Check that the permanent DTCs are cleared.

10. If the permanent DTCs are not cleared, perform the universal trip, and then check for permanent DTCs again.

HINT
- If a permanent DTC is output, the system is malfunctioning.
- If no permanent DTC is output, the system is normal.

WIRING DIAGRAM





INSPECTION PROCEDURE

CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
HINT
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

PROCEDURE

1. CHECK DTC OUTPUT (HV)

(a) Connect the Techstream to the DLC3.

(b) Turn the power switch on (IG).

(c) Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

(d) Check if DTCs are output.

Result:





B -- GO TO DTC CHART Hybrid Control System
A -- Continue to next step.

2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

NOTICE:
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.

(a) Turn the power switch off.

(b) Remove the service plug grip Hybrid Control System.

NOTICE:
After removing the service plug grip, do not turn the power switch on (READY) unless instructed by the repair manual because this may cause a malfunction.

(c) Check the connection of the low voltage connector of the inverter with converter assembly.

OK:

The connector is connected securely and there are no contact problems.

HINT
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.

NG -- CONNECT SECURELY
OK -- Continue to next step.

3. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - ENGINE ROOM NO. 2 R/B)

(a) Remove the IGCT2 relay from the engine room No. 2 relay block.

(b) Disconnect the low voltage connector from the inverter with converter assembly.

(c) Measure the resistance according to the value(s) in the table below.





Standard resistance (Check for open):





Standard resistance (Check for short):





NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR

OK -- REPLACE HYBRID VEHICLE CONTROL ECU Service and Repair