Instruments - Compass Calibration Procedure
L-SB-0052-12
June 27, 2012
Initial Calibration of Compass During PDS
Service Category
General
Section
Pre-Delivery Service
Market
USA
Applicability
Introduction
Some 2013 model year ES 350 vehicles are equipped with a compass in the rear view mirror. Use the following procedure to complete initial calibration of the compass during Pre-Delivery Service (PDS).
Warranty Information
Compass Calibration Procedure
1. Cycle the ignition switch to the "IG-ON" position and hold the "N" switch until the zone number appears on the display.
2. Push the "N" switch to select the number of the zone where the vehicle is located. See the map for zone reference.
3. Start the engine, and push the "N" switch until "CAL" appears on the display.
4. Drive the vehicle slowly at 5 mph (8 km/h), or less, in a circle until the direction is displayed. If there is NOT enough space to drive in a circle, drive around the block until the direction is displayed.
Once the direction is displayed, the calibration is complete.
NOTE
^ Do NOT perform calibration of the compass in a place where the Earth's magnetic field is subject to interference (underground parking, under a steel tower, between buildings, roof parking, near a railroad crossing, near a large vehicle, etc.).
^ During calibration, do NOT operate electric systems (moon roof, power windows, etc.)as they may interfere with the calibration.
© 2012 Lexus, a division of Toyota Motor Sales, USA