Outlet
REMOVAL1. Loosen the clamp and separate the air cleaner outlet tube and resonator from the Air Cleaner (ACL).
2. Disconnect the Mass Airflow Sensor (MAF) connector from the engine control sensor extension wiring and release the air cleaner clamp.
3. Remove the outlet side of the air cleaner.
4. Remove the MAF sensor from the outlet side of the air cleaner. For additional information, refer to Computers and Control Systems.
INSTALLATION
1. To install, reverse the removal procedure.
CAUTION: The grommet used to seal the air cleaner housing at the extension must be fully seated. Failure to do so will result in unmetered air entering the engine.
NOTE: Use the alignment notch to properly align the inlet side and outlet side of the air cleaner.