Test A

PINPOINT TEST A: THE BATTERY IS DISCHARGED OR BATTERY VOLTAGE IS LOW


Test A1-A4:






Normal Operation
The generator output is supplied through the battery positive output (B+) terminal on the back of the generator to the battery and electrical system. During normal operation the charging system warning indicator should be off with the ignition switch in the RUN position and the engine running. The charging system warning indicator should be on with the ignition switch in the RUN position and the engine off

Possible Causes
- battery
- generator
- high key-off current drain(s)