General Operating Conditions
1. Requests are serviced in the following Order: Rear Up, Front Up, Rear Down, Front Down.
2. With ignition in ``Run,'' failure to service any request within 3 minutes will result in the activation of the warning lamp. The lamp will stay on during that complete ignition cycle. However, only the request that was being serviced will be affected. The control module will continue to service all other requests as usual.
3. The rear spring solenoids will always be operated in tandem, while the front solenoids may operate independently.
4. Front and rear requests are never serviced at the same time.
5. Turning the ignition from ``Run'' to ``Off'' will clear all memory in the control module, and the warning lamp may not indicate failure when the ignition is returned to the ``On'' position. When charging the battery, ensure ignition switch is off, as damage to the compressor or compressor relay may result.