Insufficient Or No Heat
Observe the servo vacuum with the temperature lever at
85° F. If
3 in. Hg. or lower, check for hot
heater hoses to and from the
heater core and that the servo positions the blend door in the full heat position. If
over 3 in. Hg., disconnect the line from the servo and note the discharge temperature. If heat is available, check the Automatic Temperature Control
(ATC) temperature sensor cable adjustment. If OK, replace the ATC temperature sensor. If no heat is available, correct the fault in the cooling system.