Control Module HVAC: Service and Repair
REMOVAL1. Disengage glove compartment door stops and allow door to hang by hinge (illustration).
2. Working through glove compartment opening, disconnect electrical snap-lock connector and aspirator hose at blower motor controller (illustration).
3. Disconnect snap-lock connector from its mounting bracket.
4. Remove two screws retaining blower controller to evaporator case and remove controller. Do not touch fins ot controller until it has had sufficient time to cool.
INSTALLATION
1. Position blower controller on evaporator case and install two retaining screws.
2. Connect wire connector and aspirator hose to blower controller. Install connector on mounting bracket.
3. Close glove compartment door.
4. Check system for proper operation.