Floor-Defrost
Floor-Defrost Door Vacuum Motor
Removal
1. Remove the floor air distribution duct as outlined.
2. Remove the pushnut retaining the vacuum motor arm to the floor-defrost door crank arm.
3. Remove two nuts retaining the vacuum motor to the motor bracket.
4. Disengage the motor from the mounting bracket and the motor arm from the door crank arm.
5. Remove the motor from the plenum. Disconnect the vacuum hoses from the motor.
Installation
1. Connect the yellow vacuum hose to the vacuum motor end nipple and the red vacuum hose to the vacuum motor side nipple. Position motor to the floor-defrost door crank arm and the motor mounting bracket.
2. Install two nuts to retain the vacuum motor to the mounting bracket.
3. Install a new pushnut to retain motor arm on the door crank arm.
4. Install the floor air distribution duct assembly.
5. Check the system for proper operation.