EK1 Star Code 67 Short In Left Front Height Sensor Circuit
^ The air suspension control module has detected a short in the circuit used to receive signals from the left front height sensor. There are four possible causes of this short:
^ Channel "A" signal return circuit is shorted to ground.
^ Channel "B" signal return circuit is shorted to ground.
^ Left front height sensor is inoperative.
^ Air suspension control module is inoperative.
GO to EK2.