GA9 Component Check Position Circuit
^ Use a small blade screwdriver to rotate control tube on bottom of actuator to "H" (FIRM position).
^ Using an analog ohmmeter, measure resistance across Pin 1 and 2.
^ Ohmmeter reading is:
5 ohms or less -- REPLACE left rear actuator and REPEAT Service Bay Diagnostics. Reading and Clearing Diagnostic Trouble Codes
10,000 ohms or greater -- Go to GA10.