GC9 Component Check Position Circuit (H Position)
GC9 COMPONENT CHECK POSITION CIRCUIT (H POSITION)^ Use a small blade screwdriver to rotate control tube on bottom of actuator to H (FIRM position).
^ Using an analog ohmmeter, measure resistance across Pins 1 and 2.
^ Ohmmeter reading is:
5 ohms or less -- REPLACE left front actuator and REPEAT Service Bay Diagnostics. Reading and Clearing Diagnostic Trouble Codes
10,000 ohms or greater -- GO to GC1O.