IC28 Air Leak Check
^ Release STAR test button so that it remains in the up HOLD position after code 26 has been displayed for at least 5 seconds.
^ Inspect the following for air leakage:
^ Air compressor/drier assembly connection point
^ Drier assembly/air line connection point
^ Air line/air spring solenoid valve connection point
NOTE: As long as STAR test button remains in the up HOLD position the right rear air spring will continue to be inflated. When the desired amount of inflating has occurred depress STAR test button so that it remains in the TEST position.
^ Was leak path detected?
YES -- SERVICE as required, then REPEAT Service Bay Diagnostics. Reading and Clearing Diagnostic Trouble Codes
NO -- INSTALL a new air suspension control module and then REPEAT Service Bay Diagnostics. Reading and Clearing Diagnostic Trouble Codes