XB116 - Check Fuel Pump (FP) Circuit For Short to Ground
- Key "OFF".
- Install breakout box, leave Powertrain Control Module (PCM) disconnected.
- Disconnect Variable Control Relay Module (VCRM). Inspect for damaged or pushed out pins, corrosion, loose wires, etc. Service as necessary.
- Measure resistance between test pin 22 and test pin 40 at the breakout box.
- Is resistance greater than 10,000 ohms?
Yes -- Replace VCRM. Remove breakout box. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)
No -- Service Fuel Pump (FP) circuit short to ground. Remove breakout box. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)