XB146 - Check Power to Pump Circuit Continuity
- Key "OFF".
- High Speed Fuel Pump (HFP) relay disconnected.
- Variable Control Relay Module (VCRM) disconnected.
High Fuel Pump Relay Connector:
- Measure resistance between Pin 24 of the VCRM vehicle harness connector and the power-to-pump circuit at the HFP relay vehicle harness connector.
- Is resistance less than 10 ohms?
Yes -- Replace VCRM. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)
No -- Service open in power-to-pump circuit between VCRM and Fuel Pump Monitor (FPM) splice. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)