XB166 - Check HFP Circuit For Short to Power
- Key "OFF".
- High Speed Fuel Pump (HFP) relay disconnected.
- Disconnect Variable Control Relay Module (VCRM).
- Key "ON".
- Measure voltage between the HFP circuit at the HFP relay vehicle harness connector and the battery negative post.
- Key "OFF".
- Was voltage less than 1.0 volt?
Yes -- Go to XB167. XB167 - Check HFP Circuit For Short to Ground
No -- Service High Speed Fuel Pump (HFP) circuit short to power. Reconnect all components. Re-evaluate symptom.