System Deactivation Procedures
1. Record USER 1 and USER 2 pre-set radio frequencies for reprogramming following completion of service procedure.2. Disconnect battery ground cable.
3. Wait one minute. This is the time required for backup power supply in air bag diagnostic monitor to deplete its stored energy.
WARNING: The backup power supply energy must be depleted before any air bag component service is performed. To deplete backup power supply energy, disconnect the negative battery cable and wait one minute to avoid accidental deployment and possible personal injury.
Air Bag Simulator 105-00011:
4. Remove driver side air bag module from vehicle. Connect Rotunda Air Bag Simulator 105-00011 or equivalent to vehicle harness at top of steering column.
5. Remove passenger side air bag module. Install Rotunda Air Bag Simulator 105-00010 or equivalent on vehicle harness connector in place of passenger side air bag module.
WARNING: Do not place the air bag with the trim cover facing down, as the forces of the deploying air bag may cause it to ricochet and cause personal injury.
6. Reconnect battery ground cable.