Removal and Installation
REMOVAL and INSTALLATION1. Remove Intake Manifold Runner Control (IMRC) assemblies.
2. Remove E-clip retaining vacuum control linkage to lever/shaft assembly.
3. Remove adjustment screw from the vacuum control and bracket.
4. Remove two bolts retaining IMRC vacuum control and bracket to IMRC housing assembly.
5. Disconnect linkage from the lever/shaft assembly and remove vacuum control.
6. To install vacuum control and bracket assembly, reverse removal procedures. Tighten retaining bolts to 8-11.5 Nm (6-8.5 lb ft). Adjust vacuum control.