Thermostat: Service and Repair
1. Drain coolant level below upper radiator hose and thermostat housing.2. Disconnect upper radiator hose at thermostat housing, then remove two thermostat housing retaining bolts.
3. Remove O-ring seal and thermostat from intake manifold. Inspect O-ring for damage and replace if necessary.
4. Reverse procedure to install. Torque bolts to 15-22 ft lb.