Wheel Hub Face Runout
1. Position the Dial Indicator with Bracketry on the wheel hub face, as close to the outer edge as possible. Zero the indicator to allow the pointer to deflect either way.
2. Rotate the hub one full turn and note the maximum and minimum readings. The difference between the maximum and minimum readings will be the total face runout. The runout must not exceed 0.254 mm (0.010 inch).