Roof Opening Panel Control Module
REMOVAL1. Remove the roof opening panel assembly. For additional information, refer to Panel-Roof Opening Assembly.
NOTE: Make sure the roof opening glass assembly is in the closed position.
2. Remove the bolts and position the roof opening panel motor assembly aside.
3. Remove the roof opening panel control module.
1 Disconnect the electrical connectors.
2 Remove the screw.
3 Remove the roof opening panel control module.
INSTALLATION
1. Carry out the roof opening panel assembly timing. Refer to Timing Adjustment.
NOTE: Before a new roof opening panel control module can be installed, the roof opening panel and control module must be timed. The timing procedure will install the roof opening panel control module once the unit is timed.