Operation CHARM: Car repair manuals for everyone.

Torque Converter Cleaning and Inspection

1. If the torque converter is being replaced, continue with Substep 2 of Step 2.

2. If the torque converter is not being replaced, the following procedures must be performed:
1. The torque converter must be thoroughly cleaned.
^ Torque converters with drain plugs can be cleaned by using Torque Converter/Oil Cooler Cleaner.
^ Torque converters without drain plugs can be cleaned by hand. Partially fill the torque converter using only recommended transmission fluid for the applicable transmission. Hand agitate the torque converter and then thoroughly drain the fluid. Refill the torque converter with new fluid specified for transmission, and reinstall.
2. All cooler tubes must be thoroughly cleaned by backward and forward flushing.
3. If the cooler is to be replaced, use only factory approved service parts.