Test F
PINPOINT TEST F: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSETest F1-F3:
Test F4-F5:
Normal Operation
The roof opening panel motor is energized by voltage on circuit 30-AG12 (RD/GN). The roof opening panel motor is grounded through circuit 31-AG12 (BK/GN). When the roof opening panel control switch is slid to the open position and released it will connect circuit 32-AG10 (WH/BU) to circuit 9-AG7 (BN/RD) for open. When the roof opening panel control switch is slid to the close position and released it will connect circuit 33-AG10 (YE/BU) to circuit 9-AG7 (BN/RD) for close.
Possible Causes
- circuit 32-AG10 (WH/BU) shorted to ground or open
- circuit 33-AG10 (YE/BU) shorted to ground or open
- roof opening panel lifter assemblies
- roof opening panel adjustment
- roof opening panel motor
- roof opening panel control switch