Test E: The Roof Opening Panel Is Inoperative
PINPOINT TEST E: THE ROOF OPENING PANEL IS INOPERATIVEE1-E4:
E4-E6:
E7-E8:
Normal Operation
The rear battery junction box (BJB) supplies voltage to the roof opening panel motor through circuit 30-AG12 (RD/GN). The roof opening panel motor is grounded through circuit 31-AG12 (BK/GN). When the roof opening panel control switch is operated it connects the circuits for tilt up, open, or close to circuit 9-AG7 (BN/RD). Delayed accessory power is supplied by the driver door module (DDM) through circuit 10-AJ43B (GY/VT).
Possible Causes
- fuse
- circuit 9-AG7 (BN/RD) short to ground or open
- circuit 10-AJ43B (GY/VT) open
- circuit 30-AG12 (RD/GN) open
- circuit 31-AG12 (BK/GN) open
- roof opening panel control switch
- roof opening panel lifter assemblies
- roof opening panel adjustment
- roof opening panel motor