Test G: The Audio Control Module (ACM) Does Not Respond To The Diagnostic Tool
PINPOINT TEST G: THE AUDIO CONTROL MODULE (ACM) DOES NOT RESPOND TO THE DIAGNOSTIC TOOLG1-G3:
G3-G4:
G4-G5:
Normal Operation
The ACM module communicates with the diagnostic tool through the standard corporate protocol (SCP) communications network circuits 4-EG10 (GY/BK) and 5-EG10 (BU/YE). If one of the SCP communications network circuits becomes shorted to ground or voltage, or if some but not all termination resistors are lost, communications can continue. Check circuits 4-EG10 (GY/BK) and 5-EG10 (BU/YE) between the ACM C290c and the data link connector (DLC) C251. The total resistance values must not be more than 5 ohms. If the resistance is more than 5 ohms, there is either an open in circuits 4-EG10 (GY/BK) and 5-EG10 (BU/YE), damage to the DLC C251, the ACM C290c, or joint connector No. 4 C223.
Possible Causes
- SCP data plus circuit 4-EG10 (GY/BK) open
- SCP data minus circuit 5-EG10 (BU/YE) open
- joint connector No. 4 C223
- ACM C290c
- ACM