Test A: The Engine Does Not Crank
PINPOINT TEST A: THE ENGINE DOES NOT CRANKA1-A3:
A4-A7:
A7-A8:
A9-A10:
A10 Continued:
A11-A12:
A12 Continued:
A13-A15:
A15-A16:
A17:
A18-A19:
A20:
A21:
A22-A23:
Normal Operation
Under normal operation, the auxiliary junction box (AJB) supplies constant power to the starter relay on circuit 30-BB13 (RD/OG) through fuse 121 (30A). When the key is placed in the START position, with the vehicle in PARK or NEUTRAL, the TR sensor provides power on circuit 50S-BB12 (GY) and the instrument cluster provides ground on circuit 31S-BB12 (BK/YE). The coil of the relay is energized and sends power to the starter motor on circuit 50-BB10 (GY/BK).
Possible Causes
- Battery
- Ignition switch
- Starter relay
- Anti-theft system
- Circuitry
- Auxiliary junction box (AJB) fuse:
- 121 (30A)
- Battery junction box (BJB) fuse:
- 22 (20A)
- Central junction box (CJB) fuse:
- 201 (5A)