Test C: A Single Power Window Is Inoperative - RH Front
PINPOINT TEST C: A SINGLE POWER WINDOW IS INOPERATIVE - RH FRONTC1-C3:
C3-C4:
C4-C5:
Normal Operation
The RH front window smart motor receives voltage from the battery junction box (BJB) on circuit 30-AJ71 (RD/YE) and ground from circuit 31-AJ71 (BK/YE). A delayed accessory input is sent from the driver door module (DDM) to the RH front smart motor on circuit 10-AJ43 (GY/VT) so the RH front smart window motor microprocessor can determine whether or not to allow window motor operation. The RH front window control switch sends a command over circuits 7S-AJ47 (YE/BK), 8-AJ56 (WH/GN) or 7S-AJ48 (YE/VT) to the RH front smart window motor to initiate operation.
Possible Causes
- fuse
- circuit 7S-AJ47 (YE/BK) open or short to ground
- circuit 7S-AJ48 (YE/VT) open or short to ground
- circuit 8-AJ56 (WH/GN) open or short to ground
- circuit 30-AJ71 (RD/YE) open
- circuit 31-AJ71 (BK/YE) open
- BJB
- RH front window control switch
- RH front window motor