Test C: The Alarm System Does Not Arm/Disarm - Using The Remote Keyless Entry (RKE) Transmitter Or RKE Keypad
PINPOINT TEST C: THE ALARM SYSTEM DOES NOT ARM/DISARM - USING THE REMOTE KEYLESS ENTRY (RKE) TRANSMITTER OR RKE KEYPADC1-C5:
Normal Operation
The driver door module (DDM) receives lock/unlock commands from the RKE transmitter or the RKE keypad. The DDM then communicates with the lighting control module (LCM) and arms/disarms the alarm system.
Possible Causes
- LCM