Condenser to Evaporator Line
CONDENSER TO EVAPORATOR LINERemoval and Installation
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of contamination from a failed A/C compressor or damage to the suction accumulator.
1. Recover the refrigerant.
2. Remove the condenser outlet fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (11 lb-ft).
3. Disconnect the evaporator core inlet fitting.
- Discard the O-ring seals.
4. Remove the condenser-to-evaporator line.
5. To install, reverse the removal procedure.
- Install a new gasket seal and O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
6. Evacuate, leak test and charge the refrigerant system.