Suction Accumulator to Compressor Line
SUCTION ACCUMULATOR TO COMPRESSOR LINERemoval and Installation
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of contamination from a failed A/C compressor or damage to the suction accumulator.
1. Recover the refrigerant.
2. Disconnect the suction accumulator outlet fitting.
- Discard the O-ring seals.
3. Remove the compressor suction fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (11 lb-ft).
4. Remove the suction accumulator-to-compressor line.
5. To install, reverse the removal procedure.
- Install a new gasket seal and O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
6. Evacuate, leak test and charge the refrigerant system.