Suction Accumulator to Evaporator Line
SUCTION ACCUMULATOR TO EVAPORATOR LINERemoval and Installation
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of contamination from a failed A/C compressor or damage to the suction accumulator.
1. Recover the refrigerant.
2. Disconnect the suction accumulator inlet fitting.
- Discard the O-ring seals.
3. Disconnect the evaporator core outlet fitting.
- Discard the O-ring seals.
4. Remove the suction accumulator-to-evaporator line.
5. To install, reverse the removal procedure.
- Install new O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
6. Evacuate, leak test and charge the refrigerant system.