Test I: The Global Open/Closing Function Is Inoperative/Does Not Operate Correctly
PINPOINT TEST I: THE GLOBAL OPEN/CLOSING FUNCTION IS INOPERATIVE/DOES NOT OPERATE CORRECTLYI1-I3:
I3-I5:
I5-I8:
I9:
Normal Operation
When the unlock button of the remote keyless entry (RKE) transmitter is held for 2 seconds (or the driver door lock cylinder is held in the unlock position for 2 seconds) the global open activates. The smart junction box (SJB) sends a signal on circuit CPW01 (BN/BU) to activate the one-touch down operation of both front windows.
When the driver door lock cylinder is held in the lock position for 2 seconds, the global close function activates. The RKE transmitter does not have the function for global close. The SJB uses circuit CPW01 (BN/BU) to send a signal to the window motors to activate the one-touch up operation. The global open/close feature does not operate if the delayed accessory is active.
Possible Causes
- RKE transmitters
- Open, short to ground or voltage in circuit CPW01 (BN/BU)
- SJB