Keyless Entry Key-Pad: Testing and Inspection
Keyless Entry Keypad Code Programming
Remote Function Actuator (RFA) Module Keyless Entry Keypad Code Reset
NOTE: This procedure is for transferring the factory keyless entry keycode from the Smart Junction Box (SJB) and programming it into the Remote Function Actuator (RFA) Module.
1. NOTE: The keyless entry keypad code reset procedure is found on the scan tool under Toolbox, Body, Security.
Carry out the keyless entry keypad code reset on the scan tool following the on-screen instructions.
Programming a Personal Entry Code and Keypad Association to Memory Settings
NOTE: The system allows 3 personal codes to be programmed.
1. Enter the permanent factory set 5-digit keyless entry keypad code.
2. Within 5 seconds, press the 1/2 button on the keypad to activate the programming mode.
3. Enter the new 5-digit personal keyless entry keypad code. Each number must be entered within 5 seconds of each other.
4. NOTE: The permanent factory set code cannot be associated with a memory setting.
To associate the entry code with a new memory setting, enter a sixth digit to indicate which driver should be set in a memory recalled by the personal entry code:
- Pressing 1/2 recalls Driver 1 settings.
- Pressing 3/4 recalls Driver 2 settings.
- Pressing other keypad buttons or not pressing a keypad button as a sixth digit does not set a driver and will not recall a memory setting.
5. The door locks will lock and unlock to confirm the new code is programmed.
Erasing The Personal Entry Codes
1. Enter the permanent factory set 5-digit keyless entry keypad code.
2. Within 5 seconds, press the 1/2 button on the keypad and release.
3. Within 5 seconds, press and hold the 1/2 button for 2 seconds.
4. All personal codes are now erased and only the permanent factory set 5-digit code will work.