Compressor HVAC: Testing and Inspection
Climate Control System
A/C Compressor - External Leak Test
1. Install the appropriate adapter on the port of the A/C compressor, using the existing manifold retaining bolt.
2. Connect the high- and low-pressure lines of a manifold gauge set or a refrigerant recovery/recycling station to the corresponding fittings on the adapter.
3. Attach the center hose of a manifold gauge set to a refrigerant container standing in an upright position.
4. Open the low-pressure gauge valve, the high-pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.
5. Using the Refrigerant Leak Detector, check for leaks at the compressor shaft.
6. If a shaft seal leak is found, replace the compressor shaft seal. If an external leak is found, install a new A/C compressor.
7. When the leak test is complete, recover the refrigerant from the compressor.