Suction Accumulator To Evaporator Line
Suction Accumulator To Evaporator Line
Removal and Installation
1. Recover the refrigerant.
2. Disconnect the suction accumulator inlet fitting.
- Discard the O-ring seals.
3. Disconnect the evaporator core outlet fitting.
- Discard the O-ring seals.
4. Remove the suction accumulator-to-evaporator line.
5. To install, reverse the removal procedure.
- Install new O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
6. Evacuate, leak test and charge the refrigerant system.