Suction Accumulator To Evaporator Line




Suction Accumulator To Evaporator Line













Removal and Installation

1. Recover the refrigerant.

2. Disconnect the suction accumulator inlet fitting.
- Discard the O-ring seals.

3. Disconnect the evaporator core outlet fitting.
- Discard the O-ring seals.

4. Remove the suction accumulator-to-evaporator line.

5. To install, reverse the removal procedure.
- Install new O-ring seals.

- Lubricate the refrigerant system with the correct amount of clean PAG oil.

6. Evacuate, leak test and charge the refrigerant system.