Register - RH
Register - RH, MKZ
Removal and Installation
1. Remove the instrument cluster finish panel. For additional information, refer to Instrument Panel and Console Service and Repair.
2. Lower the glove compartment.
3. Remove the 4 RH instrument panel finish moulding screws.
4. Remove the RH instrument panel finish moulding.
5. Remove the RH register screw.
6. Remove the RH register.
7. To install, reverse the removal procedure.